Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump
HomeHome > Products > Inline Circulation Pump > Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump
Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Overview Product Description Detailed Photos Introduction: The type TD pumps are single stage in-line centrifugal pumps,
Basic Info
Model NO. TD
After-sales Service Online
Warranty 2 Years
Max.Head >150m
Max.Capacity >400 L/min
Driving Type Motor
Impeller Number Single-Stage Pump
Working Pressure High Pressure Pump
Influent Type of Impeller Double-Suction Pump
Position of Pump Shaft Horizontal Pump
Pump Casing Combined Horizontal Split Pumps
Mounting Height Suction Centrifugal
Impeller Closed
Usage Pump, Pumps, Condensate Pump, Ash Pumps, Circulating Pump
Transport Package Wooden Case
Specification customized
Trademark aikon
Origin China
Production Capacity 1500PCS/Year
Product Description

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Product Description

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Product Name:Electric Motor Vertical Single Stage Pipeline Centrifugal Water Pump
Material:Ductile cast iron/cast iron
Seal Material:Graphite/sillicon carbide
Max. Flow:760m3/h/3347GPM
Max. Head:88m
Max. Pressure:25bar/362.5psi
Working temperature:-15ºC~110ºC
Max. rev:2950rpm
Motor Power:0.37kw~132kw
Voltage:220V,380V
Motor:AFT,50hz/60hz
Available Connection:Flange(EN1092-2,IS07005-2)
Operated:Electric
Application Scope:Water supply ,Heating system,industrial production,fire-fighting system, air-conditioning system
Packaging Details:Wooden box
Delivery details:7-20 days after receiving payment
Brand:aikon or OEM

Detailed Photos

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Introduction:

The type TD pumps are single stage in-line centrifugal pumps, equipped with standard motor and mechanical seal.Comparing with other pumps in similar structure, these pumps are less accessible to the impurity in the liquid. The pump is designed to be pulled out from the top when disassemble.It can be repaired without affecting the pipelines. The mechanical seal for TD200 and above is cartridge mechanical seal.Motor needn't to be disassembled when replace mechanical seal. TD125~TD150 products have two structures,one is easy maintenance structure, using a catridge mechanical seal. And another is expantion shaft structure.

Working conditions:

The pumped liquid is clean, thin, non-corrosive, non-flammable, and non-explosive liquid which shall not contain any solid grain and fibre that might damage the pump mechanically or chemically.If the liquid viscosity or density is beyond the required level, the performance curves will descend and energy consumption will be increased. Liquid temperature:-15ºC~110ºC Max.Working pressure: Normal type:PN12 bar ; special type: PN 16 bar.

Installation requirements

Some detailed requirement of installation is as below:1,If the system pipeline can support the pumps, pumps with 2.2kW motor power(including 2.2kW)can be hung in line; if the system pipeline cannot support the pumps or the pump motor power is higher than 2.2kW, the pumps must be installed in brackets or base.2,Pumps with motor power lower than 2.2kW(including 2.2kW)can be installed horizontally or vertically to the pipeline.Pumps with motor power higher than 2.2kW,can only be installed vertically to the pipeline.3,The pump installation shall not allow the system pipeline tensile force to be transferred to the pump body.4,The pump should be installed in the environment with sufficient cooling and the cooling air shall not be above 40ºC.5,If the pumps are installed outdoors, there should be covers to protect electric components from water.6,For the convenience of maintenance, there should be enough space above and below the pumps.Minimum 300mm shall be kept for pumps with motor power lower than 5.5kW,and minimum 1000mmfor pumps with motor power higher than 5.5kW (including 5.5kW).7,To prevent noises and vibration and ensure the best operation, anti-vibration base shall beused in installation.Generally,cement base with the weight equal or bigger than 1.5× pump weight shall be adopted.8,ForTD32 to TD150, pumps with bases or without bases are both available for customers requirements.

Product Parameters

Definition of the model

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

More Performance please contact us.

Company Profile

Automatic Electric Circulation Pump Td80 50Hz Automatic Single Stage Vertical Inline Electric Water Pump

Packaging & Shipping

FAQ
Q1: What is your product range ?
A: We have the ability to manufacture water pumps of various materials, VFD,valves,etc.And our pumps are including slurry pumps, multi-stage pumps, pipeline pumps,sewage pumps, etc.Q2: Can you produce according to the samples ?
A: Yes, we can produce by your samples or technical drawings. We can build the molds and fixtures.
Q3: Is OEM parts available ?
A:Yes, please send me the detailed drawing. Different materials and colors are available.Q4: how can we guarantee quality ?
A: We Always a pre-production sample before mass production;Always final inspection before shipment;Q5: What are your advantages ?
A: Rapid development of new products, full range of products, professional service timely quotation and reply promptly, strict quality inspection, strong in after-sales problem solving.